Schneider 140CPU67160 | 140 CPU 671-60 Connects to the Modbus bus


Part number 140CPU67160
Manufacturer Schneider Electric
Type CPU
Type # 140 CPU 671-60
Guaranteed for 2 years
Electrical connection One connector, connector type: RJ45, used to connect the Ethernet
One connector, connector type: RJ45, used to connect to Modbus
1 hole connector, connector type: SUB-D 9, for connection to the Modbus Plus network
Product or component Unity Processor
Analog I/O numbers unlimited (up to 26 slots) - local - prohibited in hot standby applications
500 inputs, 500 outputs per network - distributed
1984 inputs, 1984 outputs - Remote
Exact time stamps for application-specific I/O
  • Schneider  140CPU67160  |  140 CPU 671-60 Connects to the Modbus bus,jlplc
  • Schneider  140CPU67160  |  140 CPU 671-60 Connects to the Modbus bus,jlplc
  • Schneider  140CPU67160  |  140 CPU 671-60 Connects to the Modbus bus,jlplc
  • Schneider  140CPU67160  |  140 CPU 671-60 Connects to the Modbus bus,jlplc

Desciption

Part number 140CPU67160
Manufacturer Schneider Electric
Type CPU
Type # 140 CPU 671-60
Guaranteed for 2 years
Electrical connection One connector, connector type: RJ45, used to connect the Ethernet
One connector, connector type: RJ45, used to connect to Modbus
1 hole connector, connector type: SUB-D 9, for connection to the Modbus Plus network
Product or component Unity Processor
Analog I/O numbers unlimited (up to 26 slots) - local - prohibited in hot standby applications
500 inputs, 500 outputs per network - distributed
1984 inputs, 1984 outputs - Remote
Exact time stamps for application-specific I/O


Number of racks 2 - Local racks
Number of distributed I/O stations 63 workstations - 1 rack - 3 distributed networks
Number of remote I/O stations 31-2 remote racks
Discrete I/O numbers 8000 inputs, 8000 outputs - distributed - per network
31744 Input, 31744 Output - Remote
Unlimited (up to 26 slots) - local - prohibited in hot standby applications



Memory Description Internal RAM 1024 kB - 512 kB for data
Scalable 8 MB - File storage using PCMCIA card
Scalable 7168 kB - program with PCMCIA card
Switch Function Key On or off the memory port
Application structure 4 auxiliary tasks - prohibited in dual-system hot backup applications
32 timer interrupt tasks - Disabled in dual-system hot backup applications
128 interrupt tasks - Disabled in dual-system hot backup application
128 I/O interrupt tasks - Disabled in dual-system hot backup applications
1 periodic quick task - Disabled in dual-system hot backup applications
1 cyclic/periodic master task
The execution time of each instruction is 0.4 to 0.5 Μs floating point number